Data Sheet MEKI™ ONE
Main Technical Features
TECHNICAL SPECIFICATIONS
Detection area (W x H) | 240 mm x 110 mm |
Conveyor speed | min. 0.1 m/s max. 1.3 m/s |
X-ray power | 30-60 kV, 0.2–2.5 mA, max 100 W |
X-ray leakage | less than 1 μSv/h |
Detector | Linear scanner, resolution 0.4 mm |
Software | Mekitec X-Ray Inspection System SW |
Operating system | Windows 10 |
Connectivity | USB, Ethernet |
HMI | 12” Color TFT LCD Screen |
Operation Temperature | 0–35 °C ambient |
Cooling | Optional air conditioner |
IP rating | IP54 |
Relative humidity | 30-85%, non-condensing |
System power supply | 110/240 VAC, 50–60 Hz |
Dimensions (W x D x H) | 1200/1280 mm x 715 mm x 2000 mm |
Weight | 155 kg |
Material | Stainless steel, brushed |
Reject | Integrated air reject with bin and standard reject confirmation |
Options | Two conveyor model, push-arm reject, hand sensors* and full reject confirmation |
System conveyor | EU and FDA food use approved conveyor belt |
Radiation protection | EN 61010-02-091, FDA CFR 21 part 1020, 40 |
Safety switches | Safety circuit CAT 3, Performance Level PL d |
*Hand sensors are required unless user access to the areas under radiation is prevented by other means such as extra shrouds or conveyor covers
DETECTION AREA
Inspected product must fit completely inside the detection area.